COVID-19 Testing Kit - Keep Your Site Open, Working & Safe

KEEP YOUR SITE OPEN AND WORKING WITH THE 15 MINUTE COVID-19 TESTING KITS!

 

Whether you are running a large site, visting domesitc  homes, regular testing gives client reassurance, keeping everyone safe and open for business. 

COVID-19 Testing Kit - Keep Your Site Open, Working & Safe

£399.99 Regular Price
£130.00Sale Price
  • KEEP YOUR SITE OPEN AND WORKING WITH THE 15 MINUTE COVID-19 TESTING KITS!

     

    USUAL RRP £20.00 + VAT

     

    NOW ONLY £7.80 A TEST (INC VAT)

     

    • QC SEALED AND APPROVED
    • Safe And Effective
    • Rapid Results in 15 Minutes 
    • Accurate to 98.7%
    • Each box contains 20 tests (£9.99 a test).  £199.99 in total, free delivery inclusive of VAT. 

    This swab test is intended for the rapid detection of COVID-19  - results available within 15 minutes with high accuracy.

     

    • It is intended to aid in the rapid diagnosis of SARS-CoV-2 infections.
    • The Healgen Covid-19 Antigen Test (Swab) does not differentiate between SARS-CoV and SARS-CoV-2.
    • Each kit contains everything required to carry out the tests, no additional equipment is needed.
    • Approved by Public Health England & validated by the UK government.
    • Results in 15 minutes.
    • Each kit includes clear instructions and is easy to use.
    • This test is not for home use.
    • Cannot be shipped to a USA address.

     

    The Healgen Covid-19 Antigen Test is one of only three UK Government approved Rapid Antigen Test. It is in high demand from schools, councils and companies.

     

    • This test is being rolled out by the UK government to mass test the population in Liverpool and other cities, click here for UK Government approval (test 3 on the list).
    • This test is intended for use by clinical professionals (eg Doctor/Practice Nurse/Employer Occupational Health depts etc).
    • An application for exceptional use of a COVID-19 rapid test, to be used by members of the public for home use, was approved on the 23rd December 2020 by the Medicines and Healthcare products Regulatory Agency (MHRA).
    • The manufacturer and reseller advice that this kit is not designed for home use.

     

    Clinical Evaluation:

    • Positive Percent Agreement (PPA): 97.3%
    • Negative  Percent Agreement (NPA): 99.6%
    • Overall Percent Agreement (OPA): 98.9%
    • Specimen: Nasopharyngeal (NP) Swab
    • Time to Results: 15 minutes
    • Shelf Life: usually 24 months from the date of manufacture

     

    Benefits:

    • Rapid testing for SARS-CoV-2 antigen within 15 minutes
    • Facilitates patient treatment decisions quickly
    • Simple, time-saving procedure
    • All necessary reagents provided & no equipment needed
    • High sensitivity and specificity

     

    Each kit contains:

    • 20 Test cassettes
    • 20 Sterile swabs
    • 20 Extraction tubes and dropper tip
    • 1 Workstation
    • 2 Buffers
    • 1 Package insert

     

    Performance Characteristics:

    • The Healgen Covid-19 Antigen Test (Swab) has been evaluated with specimens obtained from patients.
    • A commercialised molecular assay was used as the reference method.
    • The results show that the Healgen Covid-19 Antigen Test (Swab) has a high overall relative accuracy.
    • Please note these testing kits also identify the new covid-19 variant.

     

    Test Procedure:

    1. Specimen Collection

    • Use the nasopharyngeal swab supplied in the kit
    • Carefully insert the swab into the nostril of the patient, reaching the surface of posterior nasopharynx that presents the most secretion under visual inspection.
    • Swab over the surface of the posterior nasopharynx.
    • Rotate the swab several times. Withdraw the swab from the nasal cavity.

     

    2. Sample preparation

    • Insert the test extraction tube into the workstation
    • Make sure that the tube is standing firm and reaches the bottom of the workstation
    • Add 0.3 mL (about 10 drops) of the sample extraction buffer into the extraction tube.
    • Insert the swab into the extraction tube which contains 0.3 mL of the extraction buffer. Roll the swab at least 6 times while pressing the head against the bottom and side of the extraction tube. Leave the swab in the extraction tube for 1 minute.
    • Squeeze the tube several times with fingers from outside of the to immerse the swab
    • Fit the dropper tip with filter on top the extraction tube tightly
    • Remove the swab. The extracted solution will be used as test sample.

     

    3. Interpretation of Results

    • Allow the test device, test sample and buffer to equilibrate to room temperature prior to testing
    • Remove test device from the sealed pouch just prior to the testing and lay flat on work bench.
    • Ensure the nozzle with filter is fitted on to the sample extraction tube tightly.
    • Reverse the sample extraction tube, and add 4 drops (about 100 μL) of test sample by squeezing the extracted
    • solution tube into the sample window.
    • Wait for the colored band(s) to appear. The result should be read in 15 minutes.
    • Do not interpret the result after 20 minutes.

     

    Test results:

    • POSITIVE - The presence of two lines as control line (C) and test line (T) within the result window indicates a positive result.
    • NEGATIVE* - The presence of only control line (C) within the result window indicates a negative result.
    • INVALID - If the control line (C) is not visible within the result window after performing the test, the result is considered invalid. Some causes of invalid results are because of not following the directions correctly or the test may have deteriorated beyond the expiration date. It is recommended that the specimen be re-tested using a new test.

     

    Note: The intensity of color in the test line region (T) may vary depending on the concentration of analytes present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive. Please note that this is a qualitative test only and cannot determine the concentration of analytes in the specimen. Insufficient specimen volume, incorrect operating procedure or expired tests are the most likely reasons for control band failure.

     

    (*Negative results do not rule out SARS-CoV-2 infection, particularly those who have been in contact with the virus. Follow up testing with a molecular diagnostic test should be considered to rule out infection in these individuals.)

     

    In-vitro use only. Please note, each box includes 1 x work station and 2x buffer solutions, therefore it can not be split up.

     

    ***100% APPROVED BY UK GOVERNMENT*** CLICK HERE TO SEE FULL APPROVAL

     

Order a deal.jpg
Get a free quote.jpg
Register your business Box.jpg
Catalogue Box.jpg
1spends%20with%20benefits%20phone_edited